Application
Mainly used in measuring the outer diameter of pipes, wires and rods, such as communication cables, plastic wires, electric cables, optic fibers, aluminum plastic pipes, steel pipes, medical pipes and fibers; It allows both method of inline and offline measuring with feedback control, remote-end display, out-of-tolerance alarm and communication with PC.
Characteristics
1. Adopt noncontact laser scanning measurement, with no damage to the object
2. Adopt high speed data processing technology with fast sampling, high precision and reliable performance
3. Capable of PID feedback control system
4. Capable of communication with PC or PLC
5. Capable of far-end display with a second monitor
6. Capable of out-of-tolerance alarm
Technical Parameters
Measuring Range
|
1 mm - 30 mm
|
Measuring Accuracy
|
¡À0.0002mm
|
Scanning Speed
|
600 times/s
|
Outside dimension
|
377mm ¡Á 211mm ¡Á 98mm
|
Weight with stand
|
17Kg
|
Working Voltage
|
AC90V - AC280V,50/60HZ
|
Ambient Temperature
|
5¡æ-45¡æ
|
|